• Debido a la posibilidad del impácto del Tifón (Hagibis) en Japón en esta semana, algunos productos importados se podrían retrasar. Gracias por su comprensión.
    Due to the possibility of a Typhoon (Hagibis) in Japan this week, some imported products may be delayed. Thank you for your understanding.

Control & Instrumentation Cables

Days to Ship
  • All
  • Same day
  • 5 Days or Less
  • 6 Days or Less
  • 7 Days or Less
  • 8 Days or Less
  • 9 Days or Less
  • 10 Days or Less
  • 11 Days or Less
  • 12 Days or Less
  • 17 Days or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Total length(m)
Specified length(m)
Conductor cross section(mm2)
AWG size(AWG)
Number of cores(Core)
Logarithm
Finished outer diameter(mm)
Rated voltage
Shield
Sheath Characteristic
Representative standards
Sheath Color
Ground wire
Sheath Material
Insulation body materials

    For K-Thermocouple Normal Grade/Precision Grade/Heat-Resistant Flexible Precision Grade

      Cable Type OKIFLEX

        High Density Cable Type OKIFLEX

          Small Outer Diameter I/O Cable for High-Density Insulation Displacement Connection

            EMI OKIFLEX

              MVVS Cable for Less Than 100 V, Shielded

                HK-SB/20276 XL LF

                  HK/20276 XL LF

                    EMT Series

                      KPEV-SBT Series

                        MVVS Series

                          SCIC Series

                            FCPEE/F Color Identified Polyethylene Insulation Flame Resistant Polyethylene Sheath Cable

                              Instrumentation Cable J-KNPEV-SB with Polyethylene Insulated Vinyl Sheath

                                Color-Coded PE Insulation PVC Sheath Cable FCPEV-NC

                                  Color Identified PE Insulation PVC Sheath Cable FCPEV-NC-S

                                    Compensating Conductor

                                    Brand

                                    MISUMI

                                    Oki Densen

                                    Oki Densen

                                    Oki Densen

                                    Oki Densen

                                    Onamba

                                    Taiyo Cabletec

                                    Taiyo Cabletec

                                    Nagaoka Electric Wire

                                    Nagaoka Electric Wire

                                    Nagaoka Electric Wire

                                    Nagaoka Electric Wire

                                    Fuji Electric Cable

                                    JMACS

                                    JMACS

                                    JMACS

                                    Ninomiya Electric Wire

                                    Product Series

                                    For K-Thermocouple Normal Grade/Precision Grade/Heat-Resistant Flexible Precision Grade

                                    Cable Type OKIFLEX

                                    High Density Cable Type OKIFLEX

                                    Small Outer Diameter I/O Cable for High-Density Insulation Displacement Connection

                                    EMI OKIFLEX

                                    MVVS Cable for Less Than 100 V, Shielded

                                    HK-SB/20276 XL LF

                                    HK/20276 XL LF

                                    EMT Series

                                    KPEV-SBT Series【1-3 Pieces Per Package】

                                    MVVS Series

                                    SCIC Series

                                    FCPEE/F Color Identified Polyethylene Insulation Flame Resistant Polyethylene Sheath Cable

                                    Instrumentation Cable J-KNPEV-SB with Polyethylene Insulated Vinyl Sheath

                                    Color-Coded PE Insulation PVC Sheath Cable FCPEV-NC

                                    Color Identified PE Insulation PVC Sheath Cable FCPEV-NC-S

                                    Compensating Conductor

                                    Days to Ship Same day or more

                                    Stock Items Included

                                    9 Days or more 50 Days or more 9 Days or more 9 Days or more 7 Days or more 7 Days or more 7 Days or more 7 Days or more 7 Days or more 7 Days or more 7 Days or more 8 Days or more 7 Days or more 7 Days or more 10 Days or more Quote
                                    Specifications
                                    • Strand Wire
                                                                    Total length(m)1 ~ 1001001001001001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100-1 ~ 1001 ~ 1001 ~ 10020 ~ 100
                                                                    Specified length(m)------------100----
                                                                    Conductor cross section(mm2)0.30.080.050.080.080.3 ~ 0.750.128 ~ 0.3240.128 ~ 0.3240.3 ~ 0.50.3 ~ 1.250.3 ~ 20.18-0.5 ~ 0.75--1.3
                                                                    AWG size(AWG)222830282818 ~ 2222 ~ 2622 ~ 2620 ~ 2216 ~ 2214 ~ 2225-18 ~ 20---
                                                                    Number of cores(Core)-8 ~ 6420 ~ 5010 ~ 1008 ~ 502 ~ 40332 ~ 502 ~ 601 ~ 501 ~ 602 ~ 6022 ~ 1002 ~ 1002
                                                                    Logarithm-4P ~ 32P10P ~ 25P5P ~ 50P4P ~ 25P-1P ~ 25P1P ~ 25P-1P ~ 30P--1P ~ 30P1P1P ~ 50P1P ~ 50P1P
                                                                    Finished outer diameter(mm)47.3 ~ 146.6 ~ 8.35.2 ~ 9.96.1 ~ 10.25 ~ 144.3 ~ 17.73.7 ~ 16.94.6 ~ 18.95.7 ~ 26.54.3 ~ 232.6 ~ 13.54.5 ~ 23.57 ~ 7.54.5 ~ 235 ~ 243.1x5.4
                                                                    Rated voltage-300VOthersLow current circuits300V / OthersLow current circuitsLow current circuitsLow current circuitsLow current circuitsOthers300V / Low current circuitsLow current circuits---Others-
                                                                    ShieldNonePresent / NonePresentPresentPresentPresentPresentNoneNonePresentPresentPresentPresentPresentPresentPresentNone
                                                                    Sheath Characteristic------Oil resistance / Heat resistanceOil resistance / Heat resistance---Heat resistance-----
                                                                    Representative standards-ULULULUL-UL / CSA(c-UL)UL / CSA(c-UL)---------
                                                                    Sheath Color-OthersOthersOthersOthersGrayBlackBlackGrayBlackGrayOthersBlackBlackBlackBlackBlue
                                                                    Ground wire-None / OthersOthersOthersNoneNoneOthersNoneNoneOthersNoneNoneNoneNoneOthersOthers-
                                                                    Sheath MaterialOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthers
                                                                    Insulation body materialsFluorineOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersOthersPolyethylene typePolyethylene typePolyethylene typePolyethylene typeOthers

                                                                    Loading...

                                                                    1. 1

                                                                    Related Categories to Control & Instrumentation Cables