UL20276HB Cross-Linked Polyethylene UL with Shield (Part Numbers)

UL20276HB Cross-Linked Polyethylene UL with Shield
  • Revised Price

Cable for Signals with 30 V UL-AWM Standard Shield

  • c-UL
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 30 V


● Cross-linked polyethylene, more electrically stable than PVC, is used for insulation.

· Every size of the 3-core model is not a twisted pair.
· This product is compatible with "UL Traceability Program / Processed ]Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Specifications

UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image

Model Number AWG Size Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
UL20276HB 26 1P 1
~
100
(Specify 1 m
Increment)
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
24 1P
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P
22 1P
3 (Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
18P
20P
25P

More Information


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering. (Check the Specification Table for number of wire cores) 1P (1PS) is "x 2-core".

UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image
UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image
UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image

Specifications

Model Number AWG
Size
Number of Pairs *1
1P = 2 Cores
Total Length Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4 Thickness
(mm)
Material *4 Thickness
(mm)
Material *4
UL20276HB 26 1P 1
~
100
(Specify 1 m
Increment)
0.128 Twisted Pair 2 4.3 26 5.0 154 1000 500 7/0.16 0.48 Tin 0.2 Cross-linked PE 0.88 0.9 PVC ULAWM20276
c-UL
3 (Core) 3 4.4 28 4.1
2P 4 5.1 37 3.9
3P 6 5.6 45 3.3
4P 8 6.0 50 3.0
5P 10 6.4 55 2.7
6P 12 6.9 65 2.6
7P 14 6.9 70 2.4
8P 16 7.8 80 2.4
10P 20 7.8 85 2.1
12P 24 8.5 100 2.0
15P 30 9.5 120 1.9 1.0
18P 36 10.1 140 1.8
20P 40 11.0 155 1.7
25P 50 11.7 180 1.6
24 1P 0.204 2 4.7 31 6.5 98.3 7/0.20 0.61 0.25 1.11 0.9
3 (Core) 3 4.9 36 5.5
2P 4 5.8 48 5.1
3P 6 6.4 60 4.4
4P 8 6.9 70 4.0
5P 10 7.4 75 3.7
6P 12 7.9 85 3.5
7P 14 7.9 90 3.2
8P 16 9.3 115 3.2 1.0
10P 20 9.3 125 2.9
12P 24 10.3 150 2.7
15P 30 11.3 145 2.6
18P 36 11.9 170 2.4
20P 40 13.2 195 2.4
25P 50 14.1 260 2.2
22 1P 0.324 2 5.3 41 8.6 63.2 7/0.26 0.78 0.3 1.38 0.9
3 (Core) 3 5.5 47 7.2
2P 4 6.6 65 6.8
3P 6 7.4 80 5.9
4P 8 8.0 95 5.3
5P 10 8.6 105 4.9
6P 12 9.5 125 4.7 1.0
7P 14 9.5 135 4.3
8P 16 11.1 165 4.3
10P 20 11.1 185 3.9
12P 24 12.3 215 3.7
15P 30 13.6 255 3.5
18P 36 14.3 290 3.2
20P 40 16.6 355 3.2 1.4
25P 50 17.7 415 2.9



*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70
Current Reduction Factor 1.00 0.89 0.77 0.63 0.45

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) AWG26: Allowable current value when the ambient temperature is 40 °C at 1P
2.2 x 0.89 = 1.958 (A)

UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image
UL20276HB Cross-Linked Polyethylene UL with Shield:Related Image

Wire Core Identification Table

Pair Number 1 2 3 4 5 6 7 8 9 10
1st Wire Core Blue Yellow Green Red Purple Blue Yellow Green Red Purple
2nd Wire Core White Brown
Pair Number 11 12 13 14 15 16 17 18 19 20
1st Wire Core Blue Yellow Green Red Purple Blue Yellow Green Red Purple
2nd Wire Core Black Gray
Pair Number 21 22 23 24 25          
1st Wire Core Blue Yellow Green Red Purple          
2nd Wire Core Orange          
Part Number
UL20276HB-22-3P-77
UL20276HB-22-3P-78
UL20276HB-22-3P-79
UL20276HB-22-3P-80
UL20276HB-22-3P-81
UL20276HB-22-3P-82
UL20276HB-22-3P-83
UL20276HB-22-3P-84
UL20276HB-22-3P-85
UL20276HB-22-3P-86
UL20276HB-22-3P-87
UL20276HB-22-3P-88
UL20276HB-22-3P-89
UL20276HB-22-3P-90
UL20276HB-22-3P-91
UL20276HB-22-3P-92
UL20276HB-22-3P-93
UL20276HB-22-3P-94
UL20276HB-22-3P-95
UL20276HB-22-3P-96
UL20276HB-22-3P-97
UL20276HB-22-3P-98
UL20276HB-22-3P-99
UL20276HB-22-3P-100
UL20276HB-22-4P-100
UL20276HB-22-4P-[1-99/1]
UL20276HB-22-5P-100
UL20276HB-22-5P-[1-99/1]
UL20276HB-22-6P-100
UL20276HB-22-6P-[1-99/1]
UL20276HB-22-7P-100
UL20276HB-22-7P-[1-99/1]
UL20276HB-22-8P-100
UL20276HB-22-8P-[1-99/1]
UL20276HB-22-10P-100
UL20276HB-22-10P-[1-99/1]
UL20276HB-22-12P-100
UL20276HB-22-12P-[1-100/1]
UL20276HB-22-15P-100
UL20276HB-22-15P-[1-100/1]
UL20276HB-22-18P-100
UL20276HB-22-18P-[1-100/1]
UL20276HB-22-20P-100
UL20276HB-22-20P-[1-100/1]
UL20276HB-22-25P-100
UL20276HB-22-25P-[1-100/1]
UL20276HB-24-1P-1
UL20276HB-24-1P-2
UL20276HB-24-1P-3
UL20276HB-24-1P-4
UL20276HB-24-1P-5
UL20276HB-24-1P-6
UL20276HB-24-1P-7
UL20276HB-24-1P-8
UL20276HB-24-1P-9
UL20276HB-24-1P-10
UL20276HB-24-1P-11
UL20276HB-24-1P-12
UL20276HB-24-1P-13
UL20276HB-24-1P-14
Part NumberVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Logarithm Finished outer diameter
(mm)
Other Features

6 Days or more

6770.322-3P7.4Noise Resistance

6 Days or more

6780.322-3P7.4Noise Resistance

6 Days or more

6790.322-3P7.4Noise Resistance

6 Days or more

6800.322-3P7.4Noise Resistance

6 Days or more

6810.322-3P7.4Noise Resistance

6 Days or more

6820.322-3P7.4Noise Resistance

6 Days or more

6830.322-3P7.4Noise Resistance

6 Days or more

6840.322-3P7.4Noise Resistance

6 Days or more

6850.322-3P7.4Noise Resistance

6 Days or more

6860.322-3P7.4Noise Resistance

6 Days or more

6870.322-3P7.4Noise Resistance

6 Days or more

6880.322-3P7.4Noise Resistance

6 Days or more

6890.322-3P7.4Noise Resistance

6 Days or more

6900.322-3P7.4Noise Resistance

6 Days or more

6910.322-3P7.4Noise Resistance

6 Days or more

6920.322-3P7.4Noise Resistance

6 Days or more

6930.322-3P7.4Noise Resistance

6 Days or more

6940.322-3P7.4Noise Resistance

6 Days or more

6950.322-3P7.4Noise Resistance

6 Days or more

6960.322-3P7.4Noise Resistance

6 Days or more

6970.322-3P7.4Noise Resistance

6 Days or more

6980.322-3P7.4Noise Resistance

6 Days or more

6990.322-3P7.4Noise Resistance

6 Days or more

61000.322-3P7.4Noise Resistance

8 Days or more

61000.322-4P8Noise Resistance

7 Days or more

61 ~ 990.322-4P8Noise Resistance

8 Days or more

61000.322-5P8.6Noise Resistance

7 Days or more

61 ~ 990.322-5P8.6Noise Resistance

8 Days or more

61000.322-6P9.5Noise Resistance

7 Days or more

61 ~ 990.322-6P9.5Noise Resistance

8 Days or more

61000.322-7P9.5Noise Resistance

7 Days or more

61 ~ 990.322-7P9.5Noise Resistance

8 Days or more

61000.322-8P11.1Noise Resistance

7 Days or more

61 ~ 990.322-8P11.1Noise Resistance

8 Days or more

61000.322-10P11.1Noise Resistance

7 Days or more

61 ~ 990.322-10P11.1Noise Resistance

9 Days or more

61000.322-12P12.3Noise Resistance

7 Days or more

61 ~ 1000.322-12P12.3Noise Resistance

9 Days or more

61000.322-15P13.6Noise Resistance

7 Days or more

61 ~ 1000.322-15P13.6Noise Resistance

9 Days or more

61000.322-18P14.3Noise Resistance

7 Days or more

61 ~ 1000.322-18P14.3Noise Resistance

9 Days or more

61000.322-20P16.6Noise Resistance

7 Days or more

61 ~ 1000.322-20P16.6Noise Resistance

9 Days or more

61000.322-25P17.7Noise Resistance

7 Days or more

61 ~ 1000.322-25P17.7Noise Resistance

Quote

610.224-1P4.7Noise Resistance

Quote

620.224-1P4.7Noise Resistance

Quote

630.224-1P4.7Noise Resistance

Quote

640.224-1P4.7Noise Resistance

Quote

650.224-1P4.7Noise Resistance

Quote

660.224-1P4.7Noise Resistance

Quote

670.224-1P4.7Noise Resistance

Quote

680.224-1P4.7Noise Resistance

Quote

690.224-1P4.7Noise Resistance

Quote

6100.224-1P4.7Noise Resistance

Quote

6110.224-1P4.7Noise Resistance

Quote

6120.224-1P4.7Noise Resistance

Quote

6130.224-1P4.7Noise Resistance

Quote

6140.224-1P4.7Noise Resistance

Loading...

Basic Information

Rated voltage For Weak Current Circuit Shield Yes Sheath Characteristic Oil Resistant
Representative standards UL / CSA (c-UL) Sheath Color Black Sheath Material PVC
Insulation body materials Polyethylene

Additional Products in this Category

Tech Support