NA3UCSB UL/CE Compliant with Shield (Part Numbers)

NA3UCSB UL/CE Compliant with Shield
  • Volume Discount
  • Price Down

300 V UL/CE Compatible Cable with Shield

  • c-UL
  • CE-Compliant
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • 300 V
  • European Standards 300 / 500 V


· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

Specifications

NA3UCSB UL/CE Compliant with Shield:Related Image

Model Number AWG
Size
Number of Cores
NA3UCSB 20 2
3
4
6
8
10
12
16
20
18 2
3
4
6
8
10
12
16 2
3
4
6
8
10
14 2
3
4



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NA3UCSB UL/CE Compliant with Shield:Related Image
NA3UCSB UL/CE Compliant with Shield:Related Image
NA3UCSB UL/CE Compliant with Shield:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
(mm2) *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm) *5
Approximate
Mass
kg / km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification Sample
Provided* 4
Allowable Current
A (30°C)* 2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / 5 Min
Structure
Pc / mm
Outer Diameter
Approx. (mm)
Plating *3 Thickness
(mm)
Material *3 Thickness
(mm)
Material *3
NA3UCSB
20 2 0.5 Core / Layer
Stranding
2 7 63 9 35.4 50 2000 21/0.18 0.95 Tin 0.6 PVC 2.15 1 PVC ULAWM2517
c-UL
CE Supported
3 3 7.3 77 7 1
4 4 7.9 88 6 1
6 6 9.2 121 5 1
8 8 10.8 159 4 1.1
10 10 11.8 183 4 1.2
12 12 12.1 207 3 1.2
16 16 13.6 268 3 1.3
20 20 15.1 323 3 1.4
18 2 0.75 2 7.5 77 12 22.3 34/0.18 1.21 0.6 2.41 1
3 3 7.9 91 10 1
4 4 8.5 108 8 1
6 6 10 152 7 1
8 8 11.9 209 6 1.2
10 10 12.8 236 5 1.2
12 12 13.5 281 5 1.3
16 2 1.25 2 8.5 100 17 14 53/0.18 1.51 0.7 2.91 1
3 3 9 120 13 1
4 4 9.8 150 12 1
6 6 11.9 217 9 1.2
8 8 14 292 8 1.3
10 10 15.3 345 7 1.4
14 2 2.0 2 9.8 138 23 8.75 41/0.26 1.92 0.8 3.52 1
3 3 10.6 177 19 1.1
4 4 11.5 210 16 1.1



*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.90 0.75 0.73 0.65 0.56 0.44 0.37

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG20 2-core when the ambient temperature is 40°C
9 × 0.9 = 8.1 (A)

NA3UCSB UL/CE Compliant with Shield:Related Image
NA3UCSB UL/CE Compliant with Shield:Related Image

Part Number
Part NumberVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Finished outer diameter
(mm)
Shield Ground wire Power supply/signal Other Features

Loading...

Basic Information

Rated voltage 300 V Sheath Characteristic Oil Resistant Representative standards UL / CE / CSA (c-UL)
Sheath Color Navy Blue Sheath Material PVC Insulation body materials PVC

Additional Products in this Category

Tech Support

Automation Components Group
Tel:+52-442-672-7661
Mon. - Fri. 8 a.m. - 6 p.m. Sat. 8 a.m. - 12 p.m