NA6UCR Highly Flexible UL/CE Compliant

NA6UCR Highly Flexible UL/CE Compliant
  • Volume Discount

600 V UL / CE Supported Mobile Power Supply Cable

  • CSA
  • CE-Compliant
  • VW-1
  • ULAWM
  • Heat-Resistant
  • Oil-Resistant
  • Strand Wire
  • Thinned Wire Conductor
  • 600 V
  • European Standards 300 / 500 V


● It has outstandingly excellent bending property.
● Movable, core reinforced cables for 600V rated UL / CE power supplies. (CE: 300 / 500V Rated)


 
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Specifications

NA6UCR Highly Flexible UL/CE Compliant:Related Image
* Before ordering, confirm that the following symbols in the order (if any) are correct: "( = single-byte bracket"; "1 = One"; "I = i"; "0 = zero"; "O = oh".

Model Number AWG Size Number of Cores Total Length
or
Specified Length
NA6UCR 20 2 1
~
100
(Specify 1 m
Increment)
/
500
/
1000
3
4
6
8
10
20
18 2
3
4
6
8
10
12
16 2
3
4
6
8
10
14 2
3
4
6
12 4
10 4



Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
* 1 Stock products are indicated with T or A in the price column at right.
* 2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
* 3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).

More Information

NA6UCR Highly Flexible UL/CE Compliant:Related Image

NA6UCR Highly Flexible UL/CE Compliant:Related ImageNA6UCR Highly Flexible UL/CE Compliant:Related Image

NA6UCR Highly Flexible UL/CE Compliant:Related Image

NA6UCR Highly Flexible UL/CE Compliant:Related Image
NA6UCR Highly Flexible UL/CE Compliant:Related Image

Specifications

Model Number AWG
Size
Number of Cores Estimated
Section Area
( mm2) *1
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter *4
(mm)
Approximate
Mass
kg/km
Electrical Properties Conductor Insulation Wire Core
Outer Diameter
Approx. (mm)
Sheath Specification
Allowable Current
A (30°C) *2
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Maximum Voltage
V / 5 Minutes
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *3 Thickness
(mm)
Material *3 Thickness
(mm)
Material *3
NA6UCR 20 2 0.5 Core / Layer
Stranding
2 9.1 89 10 39.3 50 2000 6/18/0.08 1.1 N/A 0.85 PVC 2.8 1.7 PVC ULAWM
2501
CSA
CE Supported
3 3 9.5 103 8
4 4 10.3 122 7
6 6 11.9 164 6
8 8 13.6 221 5
10 10 14.7 242 4
20 20 18.4 412 3
18 2 0.75 2 9.5 101 13 25.3 50 2000 6/28/0.08 1.3 0.85 3.0 1.7
3 3 10.0 119 10
4 4 10.7 141 9
6 6 12.5 195 7
8 8 14.3 250 6
10 10 15.5 295 5
12 12 16.0 331 5
16 2 1.25 2 10.3 123 17 16.1 50 2000 6/44/0.08 1.7 0.85 3.4 1.7
3 3 10.8 146 14
4 4 11.7 178 12
6 6 13.7 246 10
8 8 15.8 322 8
10 10 17.1 383 7
14 2 2 2 11.1 150 23 9.87 50 2000 6/69/0.08 2.1 0.85 3.8 1.7
3 3 11.7 185 19
4 4 12.7 226 16
6 6 14.9 317 13
12 4 3.5 4 13.9 298 22 6.08 50 2000 6/71/0.10 2.6 0.85 4.3 1.7
10 4 5 4 15.6 407 30 3.86 50 2000 6/112/0.10 3.3 0.85 5.0 1.7



*1 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*2 The value of allowable current is to be used only as a reference value and is not guaranteed.
*3 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*4 For the outer diameter size of cables, wire sheath (coat), etc., refer to
"Finished Outer Diameter" in the table above. 

Current Reduction Factor

Ambient Temperature (°C) 30 40 50 60 70 80 90 100
Current Reduction Factor 1.00 0.90 0.75 0.73 0.65 0.56 0.44 0.27

Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG20 2-core when the ambient temperature is 40°C
10 × 0.9 = 9 (A)

Part Number
NA6UCR-10-4-100
NA6UCR-10-4-1000
NA6UCR-10-4-500
NA6UCR-10-4-[1-99/1]
NA6UCR-12-4-100
NA6UCR-12-4-1000
NA6UCR-12-4-500
NA6UCR-12-4-[1-99/1]
NA6UCR-14-2-100
NA6UCR-14-2-1000
NA6UCR-14-2-500
NA6UCR-14-2-[1-100/1]
NA6UCR-14-3-100
NA6UCR-14-3-500
NA6UCR-14-3-[1-100/1]
NA6UCR-14-4-100
NA6UCR-14-4-500
NA6UCR-14-4-[1-100/1]
NA6UCR-14-6-100
NA6UCR-14-6-1000
NA6UCR-14-6-500
NA6UCR-14-6-[1-99/1]
NA6UCR-16-2-1
NA6UCR-16-2-2
NA6UCR-16-2-3
NA6UCR-16-2-4
NA6UCR-16-2-5
NA6UCR-16-2-6
NA6UCR-16-2-7
NA6UCR-16-2-8
NA6UCR-16-2-9
NA6UCR-16-2-10
NA6UCR-16-2-11
NA6UCR-16-2-12
NA6UCR-16-2-13
NA6UCR-16-2-14
NA6UCR-16-2-15
NA6UCR-16-2-16
NA6UCR-16-2-17
NA6UCR-16-2-18
NA6UCR-16-2-19
NA6UCR-16-2-20
NA6UCR-16-2-21
NA6UCR-16-2-22
NA6UCR-16-2-23
NA6UCR-16-2-24
NA6UCR-16-2-25
NA6UCR-16-2-26
NA6UCR-16-2-27
NA6UCR-16-2-28
NA6UCR-16-2-29
NA6UCR-16-2-30
NA6UCR-16-2-31
NA6UCR-16-2-32
NA6UCR-16-2-33
NA6UCR-16-2-34
NA6UCR-16-2-35
NA6UCR-16-2-36
NA6UCR-16-2-37
NA6UCR-16-2-38
Part NumberVolume DiscountDays to Ship RoHSTotal length
(m)
Conductor cross section
(mm2)
AWG size
(AWG)
Number of cores
(Core)
Finished outer diameter
(mm)
Ground wire Power supply/signal Other Features

7 Days or more

6100510415.6GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

61000510415.6GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

6500510415.6GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days or more

61 ~ 99510415.6GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

61003.512413.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

610003.512413.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

65003.512413.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days or more

61 ~ 993.512413.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6100214211.1-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

61000214211.1-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

6500214211.1-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days

61 ~ 100214211.1-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6100214311.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

Quote

6500214311.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days

61 ~ 100214311.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6100214412.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

Quote

6500214412.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days

61 ~ 100214412.7GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable
Available

7 Days or more

6100214614.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

61000214614.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

7 Days or more

6500214614.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

5 Days or more

61 ~ 99214614.9GY (Green / Yellow)For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

611.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

621.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

631.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

641.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

651.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

661.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

671.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

681.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

691.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6101.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6111.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6121.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6131.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6141.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6151.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6161.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6171.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6181.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6191.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6201.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6211.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6221.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6231.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6241.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6251.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6261.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6271.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6281.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6291.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6301.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6311.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6321.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6331.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6341.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6351.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6361.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6371.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

6 Days or more

6381.2516210.3-For Power SupplyVibration-resistant, Flexible, Pliable, Elastic Carrier-tested Cable

Loading...

Basic Information

Rated voltage 600V Shield N/A Sheath Characteristic Oil Resistant
Representative standards UL / CE / CSA (c-UL) Sheath Color Navy Sheath Material PVC
Insulation body materials PVC

Additional Products in this Category

Tech Support