• Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 p.m. 9/22/2018 to 4:00 p.m. (CDT) 9/23/2018. We apologize for the inconvenience.

Bimetal Thermostats

Bimetal Thermostats:
・Materials
[ M ] Material: Heater : Ceramic (Steatite Type)
Cap : Aluminum
Bimetal : Disk Bimetal

Specifications

Part Number
MBMS080
Part NumberRated Operating Temperature (°C)
TypeNo.
MBMS08080±5
100100±5
120120±5
140140±5
160160±5
180180±5
200200±5

Part Number 

  • Incomplete part number.
    Please use left hand selections to complete a part number.
Loading...
Part Number
MBMS080
MBMS100
MBMS120
MBMS140
MBMS160
MBMS180
MBMS200
Part NumberVolume DiscountDays to Ship RoHSControl Method Input Operating Temperature Rating
(℃)
Available

6 Days or more

6ThermostatsHeater Parts080(80±5)
Available

6 Days or more

6ThermostatsHeater Parts100(100±5)
Available

6 Days or more

6ThermostatsHeater Parts120(120±5)
Available

6 Days or more

6ThermostatsHeater Parts140(140±5)
Available

6 Days or more

6ThermostatsHeater Parts160(160±5)
Available

6 Days or more

6ThermostatsHeater Parts180(180±5)
Available

6 Days or more

6ThermostatsHeater Parts200(200±5)

Loading...

  1. 1

Lead Time

More Information

■Features
· Bimetal of automatic return type.
 · It energizes (NC) when the power is turned on and the contact point shuts off when it reaches to the operation temperature rate (OFF) and electricity is turned off. It automatically recovers when it is below the rated operating temperature.
(Structure)
Principle of Operation: Bimetal Non-energizing Type Single Pole Single Throw Operating Temperature One Point Fixed Type
Operating Method: OFF when temperature rises, and ON when temperature drops
(Electric Rating)
Resistance Load AC125V/15A AC250V/7.5A (Minimum Current: 0.1A)
(Contact Resistance)
50mΩ or less according to minute current ohmmeter (DC6V/0.1A) (Initial Value)
(Insulation Resistance)
100MΩ or more in DC500V mega in the charge part and non-charge part
(Insulation Resistance)
AC1500V/min or AC1800V/sec in the charge part and non-charge part
(Leakage current: 10mA)
(ON/OFF Life Span Test)
The thermal ON/OFF operation is done 10,000 times at the load of rated current and voltage.
Insulation Resistance: 50MΩ; Contact resistance: 100mΩ or less
 

Basic Information

Type Bimetal

Additional Products in this Category

Complementary Products

Customers Who Viewed This Item Also Viewed

Tech Support

Automation Components Group
Tel:+52-442-672-7661
Mon. - Fri. 8 a.m. - 6 p.m. Sat. 8 a.m. - 12 p.m